147   Form of construction certificate
(cf clause 79I of EP&A Regulation 1994)
(1)  A construction certificate must contain the following:
(a)  the identity of the certifying authority that issued it, including, in a case where the certifying authority is an accredited body corporate, the identity of the individual who issued the certificate on behalf of the body corporate,
(b)  if the certifying authority is an accredited certifier, the accreditation number of the certifying authority, including, in a case where the certifying authority is an accredited body corporate, the accreditation number of the individual who issued the certificate on behalf of the body corporate,
(b1)  if the certifying authority is an accredited certifier who is an individual, the signature of the accredited certifier,
(b2)  if an individual issued the certificate on behalf of the certifying authority, the signature of the individual who issued the certificate,
(c)  the registered number and date of issue of any relevant development consent,
(d)  the date of the certificate,
(e)  a statement to the effect that work completed in accordance with documentation accompanying the application for the certificate (with such modifications verified by the certifying authority as may be shown on that documentation) will comply with the requirements of this Regulation as are referred to in section 81A (5) of the Act,
(f)  the classification (in accordance with the Building Code of Australia) of the building to which the certificate relates.
(1A)  A construction certificate may indicate different classifications for different parts of the same building.
(2)  A construction certificate for a building must be accompanied by a fire safety schedule for the building (if a fire safety schedule is required under Part 9).
(3)  Subclause (2) does not apply to a class 1a or class 10 building within the meaning of clause 167.