3A.13   Setbacks and maximum floor area for balconies, decks, patios, terraces and verandahs
(1)  The total floor area of all balconies, decks, patios, terraces and verandahs on a lot must not be more than 12m2 if:
(a)  any part of the structure is within 6m from a side or the rear boundary, and
(b)  the structure has any point of its finished floor level more than 2m above ground level (existing).
(2)  A balcony, deck, patio, terrace or verandah must not have any point of its finished floor level:
(a)  if it is located within 3m of a side or the rear boundary—more than 2m above ground level (existing), or
(b)  if it is located more than 3m but not more than 6m from a side or the rear boundary—more than 3m above ground level (existing), or
(c)  if it is located more than 6m from a side or the rear boundary—more than 4m above ground level (existing).
(3)  Any detached balcony, deck, patio, terrace or verandah (including any alterations or additions to the detached balcony, deck, patio, terrace or verandah) must not have a floor level that is more than 600mm above ground level (existing).
(4)  This clause does not apply to a balcony, deck, patio, terrace or verandah that is located on the front elevation of a dwelling house unless the dwelling house is located on a battle-axe lot.
Note.
 Development identified in this clause may require privacy screens under clause 3A.23.